SYSMAC CP1H Programmable Controller

Multi-functionality Condensed into an All-in-one Package. Expanded Range of Applications with Built-in Pulse Outputs for Axes, Analog I/O, and Serial Communications, and with a USB Port as a Standard Feature.

With accelerating globalization and the diversification of market needs, added value is being sought in equipment as never before. OMRON’s latest solution is the release of a new package-type terminal-block PLC that combines full basic functionality with advanced expandability.

  • A full complement of built-in functions enables increased applicability.

  • Reducing the design time required for expanded and more complex programming helps in giving added value to equipment.

Pulse Output Function

 

Four Axes are Standard.

Advanced Power for High-precision Positioning Control.

 

  • Electrolytic Capacitor Assembly by Electronic Component Manufacturing Equipment  

 

  • Sheet Feeding for Vertical Pillow Packer 

 

Pulse Output Function for Up to Four Axes

 

 

A Full Range of Functions

 

Original Search Function (ORG Instruction), Positioning with Trapezoidal Acceleration and Deceleration (PLS2 Instruction), Interrupt Feeding (ACC and PLS2 Instructions)

 

 

1 MHz High-speed Pulse Output

 

High-speed Pulse Output


CP1H-Y CPU Units offer built-in 1-MHz line-driver I/O.
• Line-driver outputs: Two each for CW and CCW.
• Line-driver inputs: Two each for phases A, B, and Z.
CP1H-Y CPU Units also have 20 normal I/O points (12 inputs and 8 outputs), and can provide 100-kHz high-speed counter inputs for two axes and 30-kHz pulse outputs for two axes.

 

 

    High-speed Counter Function

     

    Differential Phases for Four Axes Are Standard.

    Easily Handles Multi-axis Control with a Single Unit.

     

      • Main-axis Control for Equipment Such as Textile Machinery or Spinning Machinery  

     

      • Positioning Conveyance for Equipment Such as Building Material Manufacturing Machinery and

         Stone-cutting Machinery 

     

    Four-axis Counter Function (Single-phase or Differential Phase)

     

     

     

    Up to Eight Interrupt Inputs Can Be Used

     

    Eight interrupt inputs are built in. Quick-response inputs for pulse widths of 50 ตs.

    The interrupt inputs can also be used as single-phase counters. (Response frequency: 5 kHz total for 8 inputs)

     

    The 8 normal inputs (6 for Y CPU Units) can be selected in the PLC setup as interrupt, quick-response or counter inputs.

     

     

    Faster Instruction Process Time

     

    Compared with the CPM2A, basic instructions are processed at least six times faster and MOV instructions are process 26 times faster.

    Processing has been speeded up for not only basic instructions but for special instructions as well. Faster processing of approximately 400 instructions helps to speed up the entire system.

     

    Fast Instruction Process Time compared to previous model

     

     

     

      Analog I/O

       

      Four Input Words and Two Output Words for XA CPU Units.

      Analog Control and Monitoring with Only a Single CPU Unit.

       

        • Surface Inspections Using Inspection Devices  

       

        • Mechanisms to Prevent Careless Mistakes in Cell Production (Such as Forgetting to Tighten Screws)

       

        • Oil Pressure Control in Forming Machines

       

      Analog Control without Using Expansion Units

       

      Oil Pressure Control and Inspection Devices Application

       

       

       

        Serial Communications

         

        A Standard USB Port and Two Serial Ports Enable Connections  and Communications with a Wide Range of Components

         

         

        Serial Communication Diagram

         

         

         

        Modbus-RTU Easy Master

         

        Connecting Inverter Speed Control Is Made Simple Using the Modbus-RTU Easy Master.
        When the address, function, and data for a slave device are preset in a fixed memory area (DM Area), a message can be sent or received simply by turning ON an AR Area bit (A640.00 for port 1 or A641.00 for port 2) in the PLC.

         

        Modbus-RTU Communication Diagram

         

         

         

        Serial PLC Links

         

        When multiple boilers are being controlled, up to 10 words/Unit of data for settings and monitoring can be exchanged using data links between up to nine CP1H (or CJ1M) CPU Units. PLC Links can be used with either serial port 1 or serial port 2.

         

        Serial PLC Links

         

         

         

          Flexible System Configuration

           

          Flexibly Adjust the System Configuration to the Application by Adding Up to 7 CPM-series Expansion I/O Units, Expanding Functionality, and Connecting to Networks.

           

           

          CJ-series Special I/O Units and CPU Bus Units can be connected to meet current needs or to expand the system in the future.

           

           

            Easy Maintenance

             

            Easy Maintenance and Startup Adjustments with LCD Displays and Settings     New! 

             

            Attach an LCD Option Board to the CPU Unit to easily monitor or change data values in the PLC to visually check error status.

             

            CP1W-DAM01 LCD Option Board: The Board can be used only in the option board slot 1.

             

             

            Handy Built-in Functions Make Maintenance Easier

             

            Analog Inputs Are Made Simple


            An analog adjustment and an external analog setting input connector are provided.

             

             

            Analog adjustment and external analog setting input connector

             

             

             

            Status Displayed on 7-segment Display

            • The 7-segment display provides two display digits.

            • In addition to displaying error codes for errors detected by the PLC, codes can be displayed on the display from the ladder program.

            • The 7-segment display is useful for maintenance as well, allowing problems that arise during system operation to be grasped without using any Support Software.

            Example display: A memory error occurs in the UM.

             